Existing Davey EVO2 Rainbank Controller had Failed & Doesn't Pump Rainwater from Tank
Davey EVO2 Rainbank Controller Assembly Removed from Tank
Both EVO2 & Pump Removed from Tank
New Davey D42EVO Submersible Multistage Pump Ready to be Installed in Tank
New Davey EVO2 Rainbank Assembly Being Installed
New Davey EVO2 Rainbank Installed in Tank
Protective Cover Fitted to EVO2
Exposing Mains Water Supply Line to House. Only 125 kPa Entering the House.
Install Paver for Pump Base
Pipework & Valves for Pump being Installed
Completed Pipework with Isolation Valves & Bypass Line for Pump Servicing. Pump Set to Supply 400 kPa Water Pressure.
Pump Cover for Weather Protection Installed
Broken & Worn Impeller
Jet Assembly Blocked with Mud
Motor Fan with Rodent Nest
Fan Housing Cleaned Out & Bearings Replaced in Motor
New Impeller & Backplate Fitted with New Seals
Jet Assembly Cleaned Out & New Gasket Installed
Bench Testing Re-Assembled Pump for Leaks & Performance
Shallow Well Jet Pump for Irrigation from A Dam
Pump had Run Dry & Impeller had Seized causing Motor to Burn Out the Windings
New Davey 095S1T Shallow Well Pump installed with Torrium Controller for 'Loss of Prime' protection against Dry Running
Rainwater pit with failed Onga sump pump.
Failed Onga VF150 Sump Pump for de-watering.
Replacement Davey D15VA Sump Pump installed.
Grundfos Scala2 3-45 pump for mains pressure boosting was leaking badly and couldn't be isolated from the mains supply.
Grundfos CMB-SP-3-47-PM2 Pump installed with isolation valves and unions for future servicing.
Grundfos JP6 Pressure Pump had failed and no water was available for the house.
Replacement DAB Jetcom 132 with NXT Pro controller installed as a replacement.
Existing pump cover was re-installed
Pump was dropped off because of low flow rate.
Impeller was completely blocked with leaves and flowers.
Debris was removed from the impeller & the pump was reassembled.
Pump on the Test Bench to check for leaks & correct operation.
Before - Failed Wilo MT10 VFD Controller for Irrigation Pump.
Before - Wilo TWI04.05-12N Submersible Borehole Pump with Horizontal Mount Shroud.
After - SteadyPres variable speed controller. New wiring & pressure tank installed to suit new installation.
After - Grundfos SP5A-12 pump installed inside existing stainless steel horizontal mount shroud.
After - SteadyPres VFD controller & Grundfos pump wired up & connected to power.
After - Completed Installation
Before - Existing Ozito pump installation with garbage bin pump cover.
Before - Ozito Pump was leaking & ants had built their nest around the motor.
After - New Grundfos JP4-47PM1 jet pump installed on paver base with new pipework.
After - Pump Cover Installed for Weather Protection
Before - Failed Onga Waterswitch had been disconncted & bypassed. Note the undersized 20mm copper suction line
After - Davey KRB2 pump & Rainbank installed.
After - Davey Pump & Rainbank with upgraded 32mm suction line.
After - Pump cover installed for weather protection.
Before - Tarn tank mounted pump controls inside protective cover
Before - Faulty Tarn tank mounted pump controls.
After - Davey RB2/S Rainbank controller wall mounted with new pipework and valves.
After - Davey D42A/B submersible multistage pump connected to Rainbank controller.
After - PVC pipework painted and installation complete.